{"id":8560,"date":"2021-03-28T15:36:11","date_gmt":"2021-03-28T15:36:11","guid":{"rendered":"http:\/\/ixox.net\/?post_type=product&p=8560"},"modified":"2024-07-10T16:48:18","modified_gmt":"2024-07-10T09:48:18","slug":"master-gauges-for-air-micrometer","status":"publish","type":"product","link":"https:\/\/ixox.net\/master-gauges-for-air-micrometer\/","title":{"rendered":"Master Gauges for Air Micrometer"},"content":{"rendered":"
Gauge heads are used together with an air micrometer, which is a comparator type instrument calibrated using a pair of master rings or plugs.<\/p>\n
A pair of masters consists of upper and lower part of limit sizes.<\/p>\n
<\/p>\n
<\/p>\n
<\/p>\n
Nominal Size \u00f8D exceeded ~ less<\/span><\/td>\n | \u00f8D1<\/span><\/td>\n | K<\/span><\/td>\n | Chamfering<\/span><\/td>\n<\/tr>\n3~5<\/span><\/td>\n | 22<\/span><\/td>\n | 8<\/span><\/td>\n | 0.3<\/span><\/td>\n<\/tr>\n | 5~10<\/span><\/td>\n | 32<\/span><\/td>\n | 8<\/span><\/td>\n | 0.5<\/span><\/td>\n<\/tr>\n | 10~15<\/span><\/td>\n | 38<\/span><\/td>\n | 10<\/span><\/td>\n | 0.5<\/span><\/td>\n<\/tr>\n | 15~20<\/span><\/td>\n | 45<\/span><\/td>\n | 12<\/span><\/td>\n | 1.0<\/span><\/td>\n<\/tr>\n | 20~25<\/span><\/td>\n | 53<\/span><\/td>\n | 14<\/span><\/td>\n | 1.0<\/span><\/td>\n<\/tr>\n | 25~32<\/span><\/td>\n | 63<\/span><\/td>\n | 16<\/span><\/td>\n | 1.0<\/span><\/td>\n<\/tr>\n | 32~40<\/span><\/td>\n | 71<\/span><\/td>\n | 18<\/span><\/td>\n | 1.0<\/span><\/td>\n<\/tr>\n | 40~50<\/span><\/td>\n | 85<\/span><\/td>\n | 20<\/span><\/td>\n | 1.0<\/span><\/td>\n<\/tr>\n | 50~60<\/span><\/td>\n | 100<\/span><\/td>\n | 24<\/span><\/td>\n | 1.5<\/span><\/td>\n<\/tr>\n | 60~70<\/span><\/td>\n | 112<\/span><\/td>\n | 24<\/span><\/td>\n | 1.5<\/span><\/td>\n<\/tr>\n | 70~80<\/span><\/td>\n | 125<\/span><\/td>\n | 24<\/span><\/td>\n | 1.5<\/span><\/td>\n<\/tr>\n | 80~90<\/span><\/td>\n | 140<\/span><\/td>\n | 24<\/span><\/td>\n | 1.5<\/span><\/td>\n<\/tr>\n | 90~100<\/span><\/td>\n | 160<\/span><\/td>\n | 24<\/span><\/td>\n | 1.5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n | Master Plug Gauge:<\/span><\/strong><\/h2>\nNominal Size \u00f8D exceeded ~ less<\/span><\/td>\n | K<\/span><\/td>\n | L<\/span><\/td>\n | \u00f8d<\/span><\/td>\n<\/tr>\n | 3~6<\/span><\/td>\n | 12<\/span><\/td>\n | 26<\/span><\/td>\n | 6<\/span><\/td>\n<\/tr>\n | 6~10<\/span><\/td>\n | 16<\/span><\/td>\n | 30<\/span><\/td>\n | 7<\/span><\/td>\n<\/tr>\n | 10~14<\/span><\/td>\n | 20<\/span><\/td>\n | 38<\/span><\/td>\n | 8<\/span><\/td>\n<\/tr>\n | 14~18<\/span><\/td>\n | 24<\/span><\/td>\n | 44<\/span><\/td>\n | 10<\/span><\/td>\n<\/tr>\n | 18~24<\/span><\/td>\n | 28<\/span><\/td>\n | 52<\/span><\/td>\n | 12<\/span><\/td>\n<\/tr>\n | 24~30<\/span><\/td>\n | 32<\/span><\/td>\n | 58<\/span><\/td>\n | 15<\/span><\/td>\n<\/tr>\n | 30~40<\/span><\/td>\n | 36<\/span><\/td>\n | 68<\/span><\/td>\n | 18<\/span><\/td>\n<\/tr>\n | 40~50<\/span><\/td>\n | 42<\/span><\/td>\n | 78<\/span><\/td>\n | 22<\/span><\/td>\n<\/tr>\n | 50~65<\/span><\/td>\n | 30<\/span><\/td>\n | –<\/span><\/td>\n | 16<\/span><\/td>\n<\/tr>\n | 65~80<\/span><\/td>\n | 30<\/span><\/td>\n | –<\/span><\/td>\n | 16<\/span><\/td>\n<\/tr>\n | 80~100<\/span><\/td>\n | 36<\/span><\/td>\n | –<\/span><\/td>\n | 20<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":" |
|