{"id":8560,"date":"2021-03-28T15:36:11","date_gmt":"2021-03-28T15:36:11","guid":{"rendered":"http:\/\/ixox.net\/?post_type=product&p=8560"},"modified":"2024-07-10T16:48:18","modified_gmt":"2024-07-10T09:48:18","slug":"master-gauges-for-air-micrometer","status":"publish","type":"product","link":"https:\/\/ixox.net\/master-gauges-for-air-micrometer\/","title":{"rendered":"Master Gauges for Air Micrometer"},"content":{"rendered":"

\"D\u1ee5ngGauge heads are used together with an air micrometer, which is a comparator type instrument calibrated using a pair of master rings or plugs.<\/p>\n

A pair of masters consists of upper and lower part of limit sizes.<\/p>\n

 <\/p>\n

 <\/p>\n

<\/h2>\n

Master Ring Gauge:<\/span><\/strong><\/h2>\n

\"Master<\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Nominal Size \u00f8D exceeded ~ less<\/span><\/td>\n\u00f8D1<\/span><\/td>\nK<\/span><\/td>\nChamfering<\/span><\/td>\n<\/tr>\n
3~5<\/span><\/td>\n22<\/span><\/td>\n8<\/span><\/td>\n0.3<\/span><\/td>\n<\/tr>\n
5~10<\/span><\/td>\n32<\/span><\/td>\n8<\/span><\/td>\n0.5<\/span><\/td>\n<\/tr>\n
10~15<\/span><\/td>\n38<\/span><\/td>\n10<\/span><\/td>\n0.5<\/span><\/td>\n<\/tr>\n
15~20<\/span><\/td>\n45<\/span><\/td>\n12<\/span><\/td>\n1.0<\/span><\/td>\n<\/tr>\n
20~25<\/span><\/td>\n53<\/span><\/td>\n14<\/span><\/td>\n1.0<\/span><\/td>\n<\/tr>\n
25~32<\/span><\/td>\n63<\/span><\/td>\n16<\/span><\/td>\n1.0<\/span><\/td>\n<\/tr>\n
32~40<\/span><\/td>\n71<\/span><\/td>\n18<\/span><\/td>\n1.0<\/span><\/td>\n<\/tr>\n
40~50<\/span><\/td>\n85<\/span><\/td>\n20<\/span><\/td>\n1.0<\/span><\/td>\n<\/tr>\n
50~60<\/span><\/td>\n100<\/span><\/td>\n24<\/span><\/td>\n1.5<\/span><\/td>\n<\/tr>\n
60~70<\/span><\/td>\n112<\/span><\/td>\n24<\/span><\/td>\n1.5<\/span><\/td>\n<\/tr>\n
70~80<\/span><\/td>\n125<\/span><\/td>\n24<\/span><\/td>\n1.5<\/span><\/td>\n<\/tr>\n
80~90<\/span><\/td>\n140<\/span><\/td>\n24<\/span><\/td>\n1.5<\/span><\/td>\n<\/tr>\n
90~100<\/span><\/td>\n160<\/span><\/td>\n24<\/span><\/td>\n1.5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Master Plug Gauge:<\/span><\/strong><\/h2>\n

\"Master<\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Nominal Size \u00f8D exceeded ~ less<\/span><\/td>\nK<\/span><\/td>\nL<\/span><\/td>\n\u00f8d<\/span><\/td>\n<\/tr>\n
3~6<\/span><\/td>\n12<\/span><\/td>\n26<\/span><\/td>\n6<\/span><\/td>\n<\/tr>\n
6~10<\/span><\/td>\n16<\/span><\/td>\n30<\/span><\/td>\n7<\/span><\/td>\n<\/tr>\n
10~14<\/span><\/td>\n20<\/span><\/td>\n38<\/span><\/td>\n8<\/span><\/td>\n<\/tr>\n
14~18<\/span><\/td>\n24<\/span><\/td>\n44<\/span><\/td>\n10<\/span><\/td>\n<\/tr>\n
18~24<\/span><\/td>\n28<\/span><\/td>\n52<\/span><\/td>\n12<\/span><\/td>\n<\/tr>\n
24~30<\/span><\/td>\n32<\/span><\/td>\n58<\/span><\/td>\n15<\/span><\/td>\n<\/tr>\n
30~40<\/span><\/td>\n36<\/span><\/td>\n68<\/span><\/td>\n18<\/span><\/td>\n<\/tr>\n
40~50<\/span><\/td>\n42<\/span><\/td>\n78<\/span><\/td>\n22<\/span><\/td>\n<\/tr>\n
50~65<\/span><\/td>\n30<\/span><\/td>\n–<\/span><\/td>\n16<\/span><\/td>\n<\/tr>\n
65~80<\/span><\/td>\n30<\/span><\/td>\n–<\/span><\/td>\n16<\/span><\/td>\n<\/tr>\n
80~100<\/span><\/td>\n36<\/span><\/td>\n–<\/span><\/td>\n20<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"