Ojiyas Air Micrometer – Công Ty TNHH ThÆ°Æ¡ng Mại Dịch Vá»?Tinh Hà //ixox.net Wed, 10 Jul 2024 09:45:06 +0000 en-US hourly 1 //wordpress.org/?v=5.7.12 //ixox.net/wp-content/uploads/2021/01/cropped-logo-32x32.png Ojiyas Air Micrometer – Công Ty TNHH ThÆ°Æ¡ng Mại Dịch Vá»?Tinh Hà //ixox.net 32 32 Ojiyas Air Micrometer – Công Ty TNHH ThÆ°Æ¡ng Mại Dịch Vá»?Tinh Hà //ixox.net/digital-type-air-micrometer-ad-lf/ //ixox.net/digital-type-air-micrometer-ad-lf/#respond Sun, 28 Mar 2021 16:07:19 +0000 //ixox.net/?post_type=product&p=8569
  • Manufacturer: OJIYAS
  • Air micrometer is a digital precision comparator type measuring instrument based on the law of physics which state that back pressure is directly proportionate to the clearance (product dimension size) and react inversely each other.
  • » Download Catalog
  • ]]>
    Air micrometer is a digital precision comparator type measuring instrument based on the law of physics which state that back pressure is directly proportionate to the clearance (product dimension size) and react inversely each other.

    Please compare with the conventional model, it’s possible to measure with a narrow tolerances of accuracy and the actual measurement can be read quickly.

    The magnification is 10,20,50,100 and 200μm of measuring range and 5 kinds of line-up by a fixed.

    Máy đo bằng khí nén điện t�Ojiyas ad-LF

    Features:

    • Diff erential pressure sensor provides excellent stability reading
    • 2.4 inch TFT LCD screen for easy programming
    • 41 dots 3 colors LED bar (green, red and orangeï¼?/li>
    • Maximum 8 columns connections
    • 5 measurement ranges of 0.010mm ï½?0.200mm
    • Display resolution of 0.0001mm ï½?0.0020mm
    • RS485 port for serial interface connection

    VIDEO:

    Specifi cations:

    code No. Model Measurement Range Display Resolution
    92001001 ad-LF10 0.010mm 0.0001mm
    92002001 ad-LF20 0.020mm 0.0002mm
    92005001 ad-LF50 0.050mm 0.0005mm
    92010001 ad-LF100 0.100mm 0.0010mm
    92020001 ad-LF200 0.200mm 0.0020mm
    LED Bar Graph 41dot
    Digital Display TFT Color LCD
    Auto Mastering Range Master Max•Master Min ±50%
    Output Interface RS485
    Rank Function Max 100 rank
    Dimension Width Depth Height Weight
    55mm 130mm 400mm 2.4kg
    Power Supply DC9V (With AC adapter for 100V~240V
    Voltage variation rate within ±10%
    Frequency 50Hz/60Hz
    Current consumption 0.18A (MAX)
    Air Pressure 350~700kpa
    Operating Temperature 0~40oC
    Range Standard Performances
    10 µm 20 µm 50 µm 100 µm 200 µm
    Instrumental error 0.2 µm 0.4 µm 1.0 µm 2.0 µm 4.0 µm
    Repeatability 0.2 µm 0.2 µm 0.5 µm 1.0 µm 2.0 µm
    Stability of indication 0.2 µm 0.2 µm 0.5 µm 1.0 µm 2.0 µm
    Response Time Max 1.5sec Max 1.2sec
    Effective indication Range 10 µm 20 µm  50 µm 100 µm 200 µm
    ]]>
    //ixox.net/digital-type-air-micrometer-ad-lf/feed/ 0
    Ojiyas Air Micrometer – Công Ty TNHH ThÆ°Æ¡ng Mại Dịch Vá»?Tinh Hà //ixox.net/digital-type-air-micrometer-ad-l8/ //ixox.net/digital-type-air-micrometer-ad-l8/#respond Sun, 28 Mar 2021 15:58:29 +0000 //ixox.net/?post_type=product&p=8568
  • Manufacturer: OJIYAS
  • ad-L8 is a digital precision comparator type measuring instrument based on the law of physics which state that back pressure is directly proportionate to the clearance (product dimension size) and react inversely each other.
  • » Download Catalog
  • ]]>
    ad-L8 is a digital precision comparator type measuring instrument based on the law of physics which state that back pressure is directly proportionate to the clearance (product dimension size) and react inversely each other.

    ad-L8 is suitable for quality control and improving measurement efficiency since it can read promptly actual dimensions of the product.

    3 colors LED bar can help judging acceptance of the product quickly and the measured data can be processed through I/O interface.

    Features:

    • Japanese/English language selection function
    • Excellent operability provided by panel switch having 17 button keys
    • Auto master compensation function
      Auto mastering using maximum and minimum masters
    • Rank function for sorting the measured values into a group of values
      Rank is available up to 100 ranks within the OK zone
    • The maximum and minimum peak detection is available
      The peak detection can be used to measure the roundness, taper
      degree
    • Buzzer and digital display are used for exhibiting the measured
      results and their OK/NG status
      Buzzer can be set optionally from extended menu
    • USB connector, RS485 for serial interface
      To send the measured results to the computer and RS485
      compatible interface
    Máy đo bằng khí nén điện t�Ojiyas ad-L8
    Modes Digital Type Air Micrometer OJIYAS

    Specifi cations:

    Dimension Width Depth Height Weight Measurement Range 20µm 50µm 100µm 200µm
    50mm 197mm 527mm 4kg Display Resolution 0.5µm 0.5µm 1µm 2µm
    Power Supply AC100V ~ AC240V LED Bar Graph 101dot
    Power Capacity 30VA Digital Display TFT Color LCD
    Voltage Regulation within 20% Auto Mastering Range Master Max -20%

    Master Min +20%

    Frequency 50Hz/60Hz Serial Output USB port, RS485
    Air Pressure 350 ~ 700kPa Rank Function Max 100 rank
    Operating Temperature 0~40oC

     

    Range Standard Performances
    20 µm 50 µm 100 µm 200 µm
    Instrumental error 0.4 µm 1 µm 2 µm 4 µm
    Repeatability 0.2 µm 1.5 µm 1 µm 2 µm
    Stability indication 0.2 µm 0.5 µm 1 µm 2 µm
    Response Time Max 1.2 sec
    Effective Indication Range 20 µm 50 µm 100 µm 160 µm
    ]]>
    //ixox.net/digital-type-air-micrometer-ad-l8/feed/ 0
    Ojiyas Air Micrometer – Công Ty TNHH ThÆ°Æ¡ng Mại Dịch Vá»?Tinh Hà //ixox.net/lacut/ //ixox.net/lacut/#respond Sun, 28 Mar 2021 15:45:31 +0000 //ixox.net/?post_type=product&p=8565
  • Manufacturer: OJIYAS
  • Air is continuously released from gauge head when measuring or at standby. In other hand, reducing the consumption of the air is an important issue.
  • » Download Catalog
  • ]]>
    Thiết b�tạm ngắt dòng khí nén LaCUTAir is continuously released from gauge head when measuring or at standby. In other hand, reducing the consumption of the air is an important issue.

    LaCUT can stop the air released from gauge head by inserting gauge head into the LaCUT, and hence reducing the consumption of air when measurement is at standby mode.

    ]]>
    //ixox.net/lacut/feed/ 0